-40%

Fieldpiece - SC480 Wireless Power Clamp Meter

$ 143.61

Availability: 100 in stock

Description

SC480 Wireless Power Clamp Meter
One meter for every system.
Wireless direct to Job Link® System for electrical documentation
Low Pass Filter for VFD systems
Molex test leads for small circuitry
Test 3-phase with two leads
Safety rated CAT IV – 600V/CAT III – 1000V
Test HVACR electrical equipment using phase rotation, True RMS, and Inrush features. Plus connect directly with the Job Link® System app to document electrical measurements.
Electrical Testing for HVACR
True RMS readings through theclamp or leads. Inrush current mode to capture starting amps.
Test 3-Phase Power with Only Two Leads
With an alligator test lead (included) connected to L1, you can determine phase rotation with one hand.
VFDs voltage accuracy
Low Pass Filter (LPF) to remove noise and get true voltage.
Capacitance
Test questionable motor start and run capacitors. Determine when a capacitor needs to be replaced.
Molex Test Leads
Swap out your regular lead tips with the super thin Molex tips to get readings on hard to reach circuitry.
Magnetic Hanger
Hanging strap flips out to keep the meter locked in place.
And More
Works with Job Link App
°F and°C
Hold/Max/min
High voltage LED
and beeper warning
Non contact voltage
LED and beeper
Continuity LED and beeper
Diode test
Easy temp cal
Microamps DC.
Frequency (Hz) through the clamp
Low ohm range for motor windings
CATIII 1000V
CATIV 600V
0.01AAC resolution
Backlit display
Auto-Power-Off
Includes:
SC480
ATB1 Thermocouple
ASA2 Gater Clip Leads
ADLS2 Silicone Leads
ANC12 Padded Case
RCT2 Molex Tips
Specifications
Display: 10000 count dual display
Backlight: 5 minute duration with auto-off, blue color
Overrange: “OL” or “-OL” is displayed
Measurement rate: 3.3 times per second, nominal
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%RH
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80%RH (with battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C (82°F to 122°F)]
APO (Auto Power Off): Approx. 30 minutes
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 100 hours typical alkaline (No wireless, no backlight)
Low battery indication: Battery icon blinks and “batt” is displayed when the battery voltage drops below the operating level
Dimensions: 247mm(H) x 79mm(W) x 48mm(D)
Weight: Approx. 345g including battery
Altitude: Up to 6562 ft (2000m)
Overload protection: 1000VDC or 750VAC rms unless otherwise stated
Test leads: Use UL listed test leads that comply to UL61010-031 rated CATIV 600V, CATIII 1000V or above
Included test leads are gold-plated and have removable safety caps